Is it possible to REPRO the Control File of one release into the Control File of another release?

Document ID:  TEC613061
Last Modified Date:  08/02/2017
{{active ? 'Hide' : 'Show'}} Technical Document Details

Products

  • CA Detector for DB2 for z/OS
  • CA Database Management Solutions for DB2 for z/OS

Releases

  • CA Detector for DB2 for z/OS:Release:17.0.00
  • CA Detector for DB2 for z/OS:Release:18.0
  • CA Detector for DB2 for z/OS:Release:19.0

Components

  • CA Detector for DB2 for z/OS:PDT
Introduction:

This document states whether or not it's possible to REPRO the Control File of one release into the Control File of another release.

Question:

Is it possible to REPRO the Control File of one release into the Control File of another release?

Environment:
z/OS 1.11 and above.
Answer:

Using an IDCAMS REPRO utility to copy the Control File is not recommended because it can cause unpredictable results. Instead we recommend either:

     1) Using the Control File, Datastore & Profiles from the prior release with the new release. (Note: Datastores that

         were created before r15 & Profiles that were created before r14 cannot be used with this method).

     2) Allocate a Control File, Datastore & Profiles for the new release. Afterwards, copy the Old Datastore & Profiles

         into the new ones using the PDTDSCPY & PDTCPCPY Utility jobs in the <High.Level>.CDBASRC library.