Issue:

Director Panel on CA Workload Automation ESP Edition Workstation is vertical.

Cause:

When the CA Workload Automation Director is changed from horizontal to vertical on older releases the director will some times be locked and cannot be changed.

Resolution:

If it is an older build you can perform the following 

 

1. Close the Workstation 

2. Open a command prompt window, 

3. Go in the <installation directory>\bin and 4. Execute command: "Workload Director.exe" /clean /all

 

 

 

 